Fire Blanket Recall Should Cause Industry Content Warning.

2010/6/21 15:11:00 49

Recently, the European Union has issued a recall warning for fire blanket continuously.


Among them, in March, 2 countries were notified of Belgium, and the product producing country was China. Because this blanket fires 32 seconds later, once it is on fire, the product may burn users or threaten to ignite anything around the burning object. The product does not meet the relevant European standard EN 1869.


In June, Belgium issued three successive notifications for the fire blanket. The products were produced by the United Kingdom and Holland. The reason is that the user may burn the user or expand the range of fire when he uses it to extinguish the fire. The product does not meet the relevant European standard EN 1869. For more details, please refer to the recall information column of China Textile Economic information network.


In the short term, 5 recall warnings have been issued for fire blanket products, which are rare. Therefore, manufacturers producing fire blanket should immediately pay attention to testing whether their products meet the requirements of export countries, so as to avoid unnecessary losses.


Extended reading:


All the fire-extinguishing blankets sold in European Union countries must be tested by the EN 1869 standard according to the provisions of the European Union Member States and mark EN1869 on each fire blanket. If there is no such marking, the fire stations of various countries shall not be allowed to sell on the market.


The original part of the European Union's EN1869 standard contains 5 parts, together with four annexes of A, B, C and D.


Part 1,2 of the body defines the standard coverage and fire blanket.


The third part of the text puts forward special requirements for the specific structure of the product.


The key is the fourth part of the text. The specific fire protection requirements of fire blanket are specified, and the specific test requirements are given in the form of annex A, B, C and D. The test items include surface resistance test, oil pot combustion test and microbial test.


Among them, the oil burning test is the main combustion parameter of the fire blanket. The surface resistance test is arranged before the burning test of the oil pan, mainly considering the safety breakdown resistance when the fire blanket is extinguished when the electrical appliances are on fire. The standard stipulates that the resistance of any point is not less than 1 M ohm.


The life cycle of the product is mainly considered in the microbial test, so as to take certain measures to prevent the harm of microorganism to the product.


The following key oil tank combustion tests are described in detail.


In the specified environment (C.2.2), use the prescribed combustion basin, frame and combustion oil to heat the oil basin and keep the temperature up to 10 degrees /MIN. After the oil basin is ignited 25~35MIN, turn off the ignition source burner and let the oil pan continue to burn 2MIN. Completely open the fire blanket and cover the center of the oil tank with the center of the fire blanket, then adjust the position of the fire blanket and remove the Fireproof Blanket after the 17MIN. The following phenomena indicate that the fire source has been extinguished.


There is no visible flame after the fire blanket is removed.


No flame will be produced in the 3MIN when the fire blanket is removed.


During the whole testing process, the fire blanket should not be ignited and the integrity of the product should be maintained.

  • Related reading

Bangladesh 50 Thousand Garment Workers Strike For Wage Increase

Local hotspot
|
2010/6/21 15:11:00
31

College Fashion Week: Left Hand Carries Fashion &Nbsp; Right Hand Links Colleges.

Local hotspot
|
2010/6/21 15:09:00
41

Xia Liang Products: What Will Win The Favor?

Local hotspot
|
2010/6/21 15:07:00
50

China Will Become Latin America'S Second Largest Trading Partner In 5 Years.

Local hotspot
|
2010/6/21 14:58:00
34

"Euro Crisis" Stone Lions Garment Enterprises Usher In Opportunities

Local hotspot
|
2010/6/18 9:49:00
54
Read the next article

Leather Label Companies Are Going To Get Out Of The Market Predicament.

With the advent of the post crisis era, the consumption of the international market is weak, and the frequent occurrence of trade frictions has made enterprises as frightened as it is. It is difficult to expand domestic demand. In the increasingly fierce domestic market, the enterprises' fear of grabbing the market and the fierce competition has made the enterprise fear. Predicament: frequent international trade frictions: using & ldquo; going out & rdquo; strategic Kangnai a